Eclipse Next Generation PrimeFire FH Oxy-Fuel Forehearth Burner

HTS Eclipse – Next Generation PrimeFire FH

Need help selecting your product?

Send an Email Call (804) 550-7143

Overview

The Honeywell Eclipse Next Generation PrimeFire FH is an oxy-fuel forehearth burner designed for the glass industry, including Container, e-Glass, and Wool Glass (c-Glass) applications. It features a patented burner and block combination that runs cooler than previous-generation designs, extending product life while requiring minimal maintenance.

Available in three capacity sizes, the PrimeFire FH delivers significant reductions in NOx emissions and fuel consumption compared to conventional air-fuel premix forehearth equipment. The burner operates on Natural Gas and accepts a hydrogen/natural gas blend of up to 20% H2. It can be ordered with or without NPT fittings, in standard pipe lengths from 10 to 24 inches (in 2-inch increments), and with a choice of Fused Mullite or AZS refractory block material.

Features & Benefits

  • Patented burner and block combination reduces internal circulation and glass residue buildup for a virtually maintenance-free design
  • Cooler-running block and burner assembly — up to 50% longer product life compared to previous-generation designs
  • Up to 80% NOx reduction compared to air-fuel premix forehearth solutions
  • Up to 60% reduction in fuel consumption compared to air-fuel premix forehearth solutions
  • Flame length shortens as burner is turned down, providing natural turndown control in the forehearth
  • Modular design with common oxygen body — capacity can be changed by swapping fuel tubes without replacing the oxygen body
  • Available in three capacity sizes to match a range of forehearth heat demand requirements
  • Two refractory block materials available (Fused Mullite and AZS) to suit different glass types and operating conditions
  • Hydrogen-blend capable — compatible with up to 20% H2 / 80% NG fuel blends (special order)

Technical Specifications

  • Fuel Type: Natural Gas; Hydrogen/Natural Gas blend (up to 20% H2 / 80% NG)
  • Capacity Range: 17 to 50 kBTU/h (4.5 to 13 kW)
  • Fuel Flow — FH0517: 5 to 17 SCFH (0.13 to 0.43 m³/h)
  • Fuel Flow — FH0935: 9 to 35 SCFH (0.23 to 0.88 m³/h)
  • Fuel Flow — FH1350: 13 to 50 SCFH (0.33 to 1.3 m³/h)
  • Flame Length — FH0517: 3 to 7 inches
  • Flame Length — FH0935: 5 to 10 inches
  • Flame Length — FH1350: 7 to 12 inches
  • Block Dimensions: 5 x 5 x 9 inches
  • Block Material: Fused Mullite or AZS
  • Burner Material: 300-series stainless steel gas tip and oxygen nozzle
  • Inlet Orientation: Oxygen inlet at 90° to fuel inlet
  • Pipe Length Options: 10 to 24 inches in 2-inch increments (custom lengths available on request)
  • Connection Type: With or without NPT fittings; optional hoses
  • Cooling Requirement (when burner is out of service): Clean dry air, nitrogen, or oxygen
  • NOx Reduction: Up to 80% vs. air-fuel premix
  • Fuel Efficiency Improvement: Up to 60% reduction vs. air-fuel premix

Applications

  • Glass forehearth heating — the forehearth section of a glass furnace between the melter and the forming operation
  • Container glass production
  • e-Glass (fiberglass) production
  • Wool Glass (c-Glass) production
  • Oxy-fuel retrofit or replacement of air-fuel premix forehearth burner systems

Models / Configurations

  • FH0517 – Small capacity: 5 to 17 SCFH fuel flow; flame length 3 to 7 inches
  • FH0935 – Medium capacity: 9 to 35 SCFH fuel flow; flame length 5 to 10 inches
  • FH1350 – Large capacity: 13 to 50 SCFH fuel flow; flame length 7 to 12 inches

Each model is configurable with or without NPT fittings, standard pipe lengths from 10 to 24 inches (in 2-inch increments), choice of Fused Mullite or AZS block material, and optional hoses.

PrimeFire FH Accessories

  • Discharge Block, AZS (P/N 50151045-001) – Replacement AZS refractory block for forehearth applications requiring higher chemical resistance
  • Discharge Block, Mullite (P/N 50153127-001) – Replacement Fused Mullite refractory block
  • Block Gasket (P/N 50151046-001) – Replacement gasket for the burner-to-block interface
  • Flex Hose, 0.375 in. x 24 in. (P/N 10057031) – Flexible hose for oxygen supply connection
  • Flex Hose, 0.25 in. x 24 in. (P/N 10057032) – Flexible hose for fuel supply connection

Documentation

Questions?

Call us at (804) 406-4103 or send us a message here!