HTS Maxon Single Burners – Kinedizer LE Series

Need help selecting your product?

Send an Email Call (804) 550-7143

The MAXON KINEDIZER® LE is a nozzle-mix, medium-velocity burner designed for high-temperature direct-fired applications that require low NOx with very little excess air. Rugged construction with a reinforced refractory block and steel burner body/nozzle makes it a proven choice for oxidizers, process heaters, kilns, furnaces, and other demanding thermal systems. Combustion air is supplied by an external blower, and precise modulation can be achieved using MAXON MICRO-RATIO® or SMARTLINK® combustion control strategies.

Features & Benefits

  • Field-proven low emissions for high-temperature processes
  • Low NOx performance with very little excess air
  • Rugged design for oxidizers, process heaters, kilns, furnaces, dryers, and incineration applications
  • Wide capacity range with turndown up to 20:1
  • Burns natural gas, propane, and other fuel gases
  • Medium-velocity exhaust provides excellent stirring and mixing
  • Accepts preheated and vitiated combustion air (application dependent)

Model Overview

  • Product family: KINEDIZER® LE
  • Burner type: Nozzle-mix, medium-velocity (low NOx / low excess air)
  • Combustion air: External blower supplied
  • Key attribute: Hydrogen Ready Burner

Technical Specifications

  • Capacity: 158–21,980 kW (0.54–75.0 MMBtu/h)
  • Turndown: Up to 20:1
  • Maximum chamber / process temperature: 1093°C (2000°F)
  • Combustion air temperature: Ambient up to 660°F (800°F on request)
  • Combustion air O2: Can operate down to 17% O2 with preheated air (application dependent)
  • Burner design: Nozzle-mix, medium velocity
  • Fuels: Natural gas, propane (and other gaseous fuels)

Applications

  • Thermal oxidizers and incinerators
  • Process heaters
  • Kilns and furnaces
  • High-temperature dryers
  • Direct-fired high temperature air heating systems

Documentation

Brochure / Overview
Spare Parts

Additional Information

  • Final burner selection depends on furnace/oxidizer geometry, airflow, temperature, and emissions targets.
  • For low excess air performance, pair the burner with appropriate air/fuel ratio control (e.g., MICRO-RATIO® or SMARTLINK® strategies).

 