HTS Maxon 8000 Series Pneumatic Shut Off Valve
Need help selecting your product?
The Honeywell Maxon Series 8000 Pneumatic Safety Shut-Off Valve provides reliable, automatic shut-off for fuel gas service. Designed for high-pressure applications, this air-actuated valve delivers tight sealing and rapid response times for safety-critical combustion systems. It is available in multiple body sizes and configurations to meet general-purpose or hazardous-area classifications.
Features & Benefits
- Pneumatically operated safety shut-off valve for fuel gas service.
- Fast-opening and tight-sealing design for high reliability.
- Available in normally-closed or normally-open configurations.
- Supports general-purpose, non-incendive, and intrinsically safe area classifications (ATEX and Division-rated models available).
- Offered in both standard and high-pressure body constructions.
Model Overview
- Series: 8000 Pneumatic Shut-Off Valve
- Body Sizes:
- 075 – 3/4″ (DN 20)
- 100 – 1″ (DN 25)
- 125 – 1-1/4″ (DN 32)
- 150 – 1-1/2″ (DN 40)
- 200 – 2″ (DN 50)
- 250 – 2-1/2″ (DN 65)
- 300 – 3″ (DN 80)
- 400 – 4″ (DN 100)
- 600 – 6″ (DN 150)
- 800 – 8″ (DN 200)
- Flow Capacity:
- S – Standard
- C – CP Body Construction
- Pressure Rating:
- 80 – Pneumatic Standard Pressure
- 81 – Pneumatic High Pressure
- Normal Position:
- 1 – Normally Closed (Shut-Off)
- 2 – Normally Open (Vent)
- Area Classification:
- 1 – General Purpose
- 2 – Non-incendive, Class I, II, III Div. 2
- 3 – Intrinsically Safe, Class I, II, III Div. 1 (ATEX Zone 1/21 when ordered with ATEX IS solenoid)
- 4 – Valve Body Only
Technical Specifications
- Body Material: Cast or ductile iron (per model size and rating)
- Pressure Range: Standard and high-pressure options (up to 125 PSIG depending on configuration)
- Operating Temperature: Maximum ambient limit of 122°F (50°C)
- Actuation: Pneumatic cylinder operation for positive shutoff
- Mounting: Flanged or threaded per ANSI/DN sizing
- End Connections: NPT or flanged
- Approvals: FM, CSA, and ATEX options available depending on configuration
Applications
- Fuel gas shut-off for industrial furnaces, ovens, and combustion systems
- Dual-valve trains for burner safety interlocks
- Applications requiring pneumatic actuation for rapid closure
- Hazardous location installations (with appropriate solenoid options)
Documentation
- Data Sheet – Series 8000 Pneumatic Shut-Off Valves (EN).
Additional Information
- Configured Item Example: 300C8111 – 3″ CP body, high-pressure, normally-closed, general purpose.
- Segment options define valve size, flow capacity, pressure rating, normal position, and area classification.
- For hazardous or special applications, reference the ATEX-approved intrinsically safe configurations.