HTS Hauck – TBA 60 – Turbo Blower Air, Direct Drive, 60 Hz
Need help selecting your product?
Overview
The Honeywell TBA 60 is a direct drive turbo blower designed to supply air for combustion or any low-pressure air application. Available in six pressure ranges from 12 to 36 osig (52 to 155 mbar) and 63 different sizes ranging from 240 to 13,000 scfm (6.4 to 348 nm³/min), the TBA 60 delivers large or small volumes of air at constant pressures to suit a wide range of burner and process applications.
The TBA 60 features a fiberglass scroll casing with a riveted heavy-gauge aluminum turbine-bladed impeller, precisely balanced to ISO 1940-2 Grade G6.3. The casing can be rotated to any of seven discharge positions and the unit is compatible with ODP or TEFC 60 Hz, 3600 rpm standard-shaft T-frame motors in clockwise or counterclockwise rotation configurations.
Features & Benefits
- Integral molded fiberglass scroll design — more abrasion and corrosion resistant than steel blower housings for extended service life
- Riveted heavy-gauge aluminum turbine-bladed impeller precisely balanced to ISO 1940-2, Quality Grade G6.3 — eliminates vibration in operation
- Six pressure ranges from 12 to 36 osig (52 to 155 mbar) and 63 sizes from 240 to 13,000 scfm — covers a broad range of combustion air and low-pressure air requirements
- Direct drive configuration with 60 Hz, 3600 rpm T-frame motors — eliminates belt maintenance and drive losses
- Casing rotates to 7 discharge positions (8-bolt removal) — simplifies installation in any piping orientation
- Compatible with ODP or TEFC motor enclosures and both clockwise and counterclockwise rotation builds
- Efficiencies up to 50% over conventional blowers — reduced power consumption, smaller horsepower requirement for a given air volume and pressure
- Steel inlet guard included as standard
- Complete accessory line available for adapting to any piping condition or operational requirement
- Mounting suitable for floor or elevated structure with vibration isolation pads
Technical Specifications
- Pressure Range: 12 to 36 osig (52 to 155 mbar)
- Flow Range: 240 to 13,000 scfm (6.4 to 348 nm³/min)
- Number of Sizes: 63 sizes across six pressure ranges
- Drive Type: Direct drive, 60 Hz
- Motor Speed: 3600 rpm standard-shaft T-frame motor
- Motor Enclosure Compatibility: ODP or TEFC
- Rotation: Clockwise or counterclockwise (specified at time of order — impeller rotates one direction per unit)
- Housing Material: Fiberglass casing with integral molded scroll design
- Impeller: Riveted heavy-gauge aluminum, turbine-bladed
- Impeller Balance: ISO 1940-2, Quality Grade G6.3
- Impeller Locking: 3 setscrews positioned 120° apart, torqued to 400 in-lb (45 N·m)
- Discharge Positions: 7 positions; casing rotation by removing 8 bolts
- Mounting: Floor or elevated structure with vibration isolation pads
- Ambient Temperature (Max): 104°F (40°C) for Class B insulation
- Voltage Tolerance: ±10% of nameplate value
- Frequency Tolerance: ±5% of nameplate value
- Impeller Balance Standard: ISO 1940-2 (impeller balance)
Applications
- Combustion air supply for industrial burners and process heating equipment
- Low-pressure air supply for any application requiring constant pressure air delivery
- OEM burner packages requiring a direct drive, constant-pressure air blower
- Retrofit and replacement applications where belt-drive blowers are currently installed
- Industrial furnaces, ovens, kilns, and process heaters requiring reliable combustion air
Models / Configurations
- TBA 60 – Direct Drive, 60 Hz – Available in 63 sizes across six pressure ranges (12–36 osig / 52–155 mbar); specify clockwise (CW) or counterclockwise (CCW) rotation and ODP or TEFC motor enclosure at time of order. Consult the FSG TBA product range documents for complete model selection data.
- TBA 60 with Motor – Complete blower and motor assembly; refer to FSG TBA Blower product range document for size and configuration selection.
- TBA 60 without Motor – Blower only (no motor supplied); refer to FSG TBA No Motor product range document for size and configuration selection.
TBA 60 Accessories
A complete line of accessories is available for adapting the TBA 60 to any piping condition or operational requirement. Refer to the product brochure and spare parts documentation for specific accessory model numbers and compatibility.
- Vibration Isolation Pads – Required for floor or elevated structure mounting to reduce transmitted vibration
- Steel Inlet Guard – Standard intake protection; included with blower assembly
- Inlet and Outlet Adapters – Available to adapt the blower connection to various piping configurations
- Replacement Impeller Assemblies – Spare impeller assemblies available; refer to TBA 60 Spare Part List for part numbers