The Honeywell® HeatPak is a completely pre-assembled and pre-wired packaged burner system built around the time-tested Eclipse RatioAir and RatioMatic air heating burners. Each unit integrates an integral combustion air fan, a complete gas safety and control system, and a burner control unit into a single compact package — designed for fast installation in new and retrofit industrial air heating applications.
Two base configurations are available: the RatioAir HeatPak (RAHP), which uses an excess air head for higher turndown and operates in recirculating, non-recirculating, or indirect heating modes; and the RatioMatic HeatPak (RMHP), which features a patented baffle-plate burner head for a stable, uniform flame with reduced emissions, designed exclusively for hot air applications. Both types use pneumatic air/gas ratio control for modulating capacity regulation.
Features & Benefits
- Completely pre-assembled and pre-wired at the factory — reduces on-site installation time and minimizes wiring errors
- Compact integrated design with fan, gas safety system, gas control system, and burner control unit as one coordinated package
- Modulating pneumatic air/gas ratio control (RAHP and RMHP) — maintains accurate fuel-to-air ratio across the full capacity range
- RMHP patented baffle-plate burner head delivers a stable, uniform flame with reduced emissions at low process temperatures
- RAHP ThermJet excess air head provides high turndown and greater operational flexibility with straight or tapered (medium velocity) burner tube options
- Direct electrical ignition (spark electrode) with factory-preset pressure switches for safe, repeatable burner start
- Modular BCU configuration — choose BCU 570 (with optional PROFINET or Modbus TCP), BCU 370 (with optional PROFIBUS DP), or terminal box for customer-supplied controls
- Nozzle-mix burner design — gas and air mix only at the burner head, eliminating explosive gas mixtures in upstream pipework
- IC 20 actuator with three-point step or continuous (4–20 mA) control input for flexible integration into existing process temperature control systems
- Optional fan filter and gas pressure regulator GDJ available for demanding or high-pressure inlet applications
- Compliant with EN 746-2, Machinery Directive 2006/42/EC, and Low Voltage Directive 2014/35/EU
Technical Specifications
- Capacity range: 100 to 1100 kW (≈ 0.34 to 3.75 MMBtu/h) — model dependent
- Fuel types: Natural Gas L, Natural Gas H, Propane, Butane
- Minimum gas supply pressure: 50 mbar (19.7 “WC)
- Maximum gas supply pressure: 100 mbar standard; up to 400 mbar with optional GDJ pressure regulator
- Combustion chamber pressure range: -2.5 to +2.5 mbar (-0.98 to +0.98 “WC)
- Maximum combustion chamber temperature: 1050°C (~1900°F)
- Process air inlet temperature range: 20 to 150°C
- Process air outlet temperature range: 250 to 500°C (application-dependent)
- Control voltage: 120 V or 230 VAC, 50/60 Hz
- Fan voltage: 400 V, 3-phase, 50/60 Hz
- Control type: modulating
- Control input: three-point step or analogue (4–20 mA, 0–20 mA, or 0–10 V)
- Actuator running time: 30 s / 90°
- Ignition: direct electrical ignition via spark electrode
- Flame supervision: flame rod (standard); UV sensor UVS 10 or UV sensor UVC 1 for continuous operation (optional, with BCU 370 or BCU 570)
- Typical flame length: 0.5 to 1.8 m depending on model and burner type
- Sound levels: 77–85 dB(A) at 1 m without filter (varies by model)
- Fieldbus options: PROFINET or Modbus TCP (BCU 570 variants); PROFIBUS DP (BCU 370 variant)
- Recommended maintenance interval: twice per year (more frequently with contaminated media)
- Approvals: EN 746-2, Machinery Directive 2006/42/EC, Low Voltage Directive 2014/35/EU; Eurasian Customs Union compliant
Applications
- Recirculating direct-fired air heating systems (drying ovens, industrial dryers)
- Non-recirculating (static) direct-fired air heating
- Indirect air heating via heat exchanger — where combustion gases must remain separate from the product (RAHP only)
- Hot air generation for industrial processes
- Process gas heating
- Retrofit replacement of existing single-burner installations — compact design enables fast conversion
Models / Configurations
- RAHP 20.040 – RatioAir HeatPak, 100–110 kW; straight or medium velocity (tapered) burner tube; integrated fan 0.18 kW
- RAHP 20.075 – RatioAir HeatPak, 200–250 kW; straight or medium velocity burner tube; integrated fan 0.25 kW
- RAHP 20.100 – RatioAir HeatPak, 240–300 kW; straight or medium velocity burner tube; integrated fan 0.37 kW
- RAHP 20.200 – RatioAir HeatPak, 600–650 kW; straight or medium velocity burner tube; integrated fan 1.1 kW
- RAHP 20.300 – RatioAir HeatPak, 845–900 kW; straight or medium velocity burner tube; integrated fan 1.5 kW
- RMHP 30.075 – RatioMatic HeatPak, 200 kW; patented baffle-plate burner head; integrated fan 0.25 kW
- RMHP 30.100 – RatioMatic HeatPak, 350 kW; patented baffle-plate burner head; integrated fan 0.37 kW
- RMHP 30.200 – RatioMatic HeatPak, 500 kW; patented baffle-plate burner head; integrated fan 0.55 kW
- RMHP 30.300 – RatioMatic HeatPak, 750 kW; patented baffle-plate burner head; integrated fan 0.75 kW
- RMHP 30.400 – RatioMatic HeatPak, 1100 kW; patented baffle-plate burner head; integrated fan 1.5 kW
All models are configurable with BCU 570 (with optional PROFINET or Modbus TCP), BCU 570 standard, BCU 370 (with optional PROFIBUS DP), or terminal box for customer-supplied controls. Gas supply pressure options: 50–100 mbar (standard) or 100–400 mbar (with GDJ option). Flame supervision options: flame rod, UV sensor UVS 10, or UV sensor UVC 1 for continuous operation.
HeatPak Accessories
The HeatPak supports a range of field-installable accessories to suit specific installation and application requirements.
- Fan Filter (flat filter) – Optional air inlet filter for the fan housing; reduces airborne contamination entering the combustion air system; available separately
- Gas Pressure Regulator GDJ – Optional inlet pressure regulator reducing supply pressure from up to 400 mbar to 100 mbar; required for high-pressure gas supply applications
- Gas Filter GFK – Optional inline gas filter for the gas supply line
- Pressure Gauge with Capsule Element KFM – Optional inlet pressure gauge with manual cock DH for gas supply pressure monitoring
- BCM 500 Bus Module – Optional expansion module for BCU 570; enables communication, control, and visualization via PROFINET
- Actuator IC 20..T – Three-point step control actuator for the air butterfly valve
- Actuator IC 20..E – Continuous analogue control actuator (4–20 mA) for the air butterfly valve
- UV Sensor UVS 10 – Optional UV flame sensor for use with BCU 370 or BCU 570 in place of standard flame rod
- UV Sensor UVC 1 – Optional UV sensor for continuous operation; for use with BCU 370 or BCU 570